experimental
Entry: sensitivity
URI: https://registry.epos-eu.org/ncl/FAIR-Incubator/tcs-SEISMO/99
The scalar value used to convert the measured output signal (usually in voltage) to motion units. It is equivalent to the sensitivity scale factor of a normalized Laplace transfer function. For a sensor with a flat frequency response, the sensitivity corresponds to some mid-frequency level of the frequency-response amplitude for a specified frequency, often 1 Hz. Sensitivity has units of volts per input unit (e.g., volt per g for strong-motion accelerometers, volt per m/s for velocity meters or volt per rad/s for rotational sensors)
Core metadata
is a | Concept |
submitted by | Tendry R |
accepted on | 10 Feb 2022 10:24:49.743 |
Download formats available
RDF ttl | plain | with metadata |
RDF/XML | plain | with metadata |
JSON-LD | plain | with metadata |
CSV | plain | with metadata |
Export all | export |
All metadata properties
date accepted |
10 Feb 2022 10:24:49.743
|
||||
date submitted |
10 Feb 2022 10:16:37.311
|
||||
definition |
|
||||
description |
The scalar value used to convert the measured output signal (usually in voltage) to motion units. It is equivalent to the sensitivity scale factor of a normalized Laplace transfer function. For a sensor with a flat frequency response, the sensitivity corresponds to some mid-frequency level of the frequency-response amplitude for a specified frequency, often 1 Hz. Sensitivity has units of volts per input unit (e.g., volt per g for strong-motion accelerometers, volt per m/s for velocity meters or volt per rad/s for rotational sensors)
|
||||
item class |
Concept
|
||||
label |
sensitivity
|
||||
notation |
99
|
||||
register |
tcs sEISMO
|
||||
status |
status experimental
|
||||
submitter |
|
||||
type |
register item
|
||||
version info |
2
|
Pane is loading...
Select tab to expand
Definition
description |
The scalar value used to convert the measured output signal (usually in voltage) to motion units. It is equivalent to the sensitivity scale factor of a normalized Laplace transfer function. For a sensor with a flat frequency response, the sensitivity corresponds to some mid-frequency level of the frequency-response amplitude for a specified frequency, often 1 Hz. Sensitivity has units of volts per input unit (e.g., volt per g for strong-motion accelerometers, volt per m/s for velocity meters or volt per rad/s for rotational sensors)
|
label |
sensitivity
|
notation |
99
|
pref label |
sensitivity
|
type |
Concept
|
Links